Temperature

(0-300)℃ 、(0-500)℃

Pressure

(0-300) Pa、(0-1000) Pa、(0-2000) Pa

Flow speed

(1-15) m/s、(2-30) m/s、(2-40) m/s

Measure range

Min:0~5 mg/Nm3 、Max:0~200 mg/Nm3

 

Overview

EXPEC 2000 FT flue gas emission continuous monitoring system adopts Fourier transform infrared spectroscopy (FTIR) technology, through the measurement and analysis of the infrared "fingerprint" characteristic absorption spectrum of the pollutant gas components, to realize the qualitative and quantitative online monitoring of characteristic factors, such as SO2,NOX(NO, NO2),CO, CO2,HCl, HF, CH4,NH3, etc. The system consists of a gaseous pollutant monitoring subsystem, a smoke dust (particulates) monitoring subsystem, a flue gas parameter monitoring subsystem, and a data acquisition and processing subsystem, It is often used in on-line monitoring of waste incineration, on-line monitoring of ultra-low emissions, and carbon monitoring.

EXPEC 2000 FT

Standards

The product meets the requirements of below standards:

  1. “Technical Specifications for Continuous Monitoring of Flue Gas Emissions from Stationary Pollution Sources” (HJ 75-2017)
  2. “Technical Requirements and Testing Methods for Continuous Monitoring Technology System of Flue Gas Emission from Fixed Pollution Sources”(HJ 76-2017)
  3. “Pollutant Online Monitoring (Monitoring) System Data Transmission Standard” (HJ 212-2017)
  4. “Domestic Waste Incineration Fixed Source Flue Gas (Particulates, SO2, NOX, HCl, CO) Emissions Continuous Monitoring System Technical Requirements and Testing Methods (Testing Operation Instructions)” (China Environmental Monitoring Center)

Advantage

Total thermal design

The system adopts whole 180℃ high temperature heating, no cold point design, no water vapor condensation, avoid high boiling point component attachment, suitable for high temperature/high humidity/high corrosion conditions.

Highly automated

Optional analog gas generator can be used for instrument quality control and calibration, while with unattended regular automatic calibration function, high degree of automation, small maintenance.

Fully independent research and development

The core module gas chamber and interferometer in the high-performance FTIR analyzer are all independently developed, with strong anti-interference and strong stability.

Simultaneous analysis of multiple components

One machine can monitor at the same time, SO2、NOX、CO、CO2、HCl、HF、CH4 and many other factors, greatly saves the expansion costs.

Various communication methods

It has RS232/485, 4~20mA, LAN and other communication methods

Application

Specifications

Item

Inde

Item

Index

Gaseous

Pollutant    Monitoring

SO2

(0~1000)mg/m3 ,customizable

Flue gas

Parameter

Monitoring

Temperature

(0-300)℃ 、(0-500)℃

NOX

(0~1000)mg/m3 ,customizable

Pressure

(0-300)  Pa、(0-1000)  Pa、(0-2000)  Pa

CO

(0~1000)mg/m3 ,customizable

Flow speed

(1-15)  m/s、(2-30)  m/s、(2-40)  m/s

HCl

(0~1000)mg/m3 ,customizable

Particulate

Monitoring

Measure

range

Min:0~5   mg/Nm3 、Max:0~200   mg/Nm3

HF

(0~300)mg/m3 ,customizable

Zero point

drift

±2.0% F.S.

CO2

(0~30)%

Range drift

±2.0% F.S.

H2 O

(0~40)%

Spectral library

Support self-built spectral library

O2

(0~25)%

Power supply

220VAC  50Hz

Zero

point

drift

within ±2.5%   F.S.

(calculated as SO2)

Working humidity

(20-90)%  RH

Range

drift

within ±2.5%   F.S.

(calculated as SO2)

Working

temperature

(5~35)˚C