Battery powered (24 V, 19.2 Ah) or adapter powered (220 VAC, 50Hz)
(-15-45) °C
(0~95)%RH
Heating miniaturized dedicated flame ionization detector (FID)
The EXPEC 3200 Portable Methane and Non-Methane Total Hydrocarbon (benzene series) Analyzer is fully compliant with the HJ1012-2018 Technical Requirements and Test Methods for Portable Total Hydrocarbon, Methane and Non-methane Total Hydrocarbon Monitors for Ambient Air and Exhaust Gases. The technical principles of the product are in accordance with the HJ38-2107 Measurement Point Gas Chromatography for Total Hydrocarbons, Methane and Non-methane Total Hydrocarbons in Waste Gas from Stationary Pollution Sources.


The analyzer uses high temperature sample transfer and high temperature FID detection technology (up to 180°C), mitigating the loss of high boiling point and high concentration samples. The sample gas is filtered through a secondary filter and enters the quantification ring for accurate quantification, after which the sample is separated by the chromatograph into a hydrogen flame ionization (FID) detector. The FID detector is capable of accurately measuring total hydrocarbons, methane, non-methane total hydrocarbons, as well as benzene, toluene and xylene, and other characteristic factors in stationary and unorganized emissions with detection limits up to the ppb level.
|
Item |
Technical parameters |
|
Physical dimensions and weight |
Dimensions: 413 x 251 x 348 mm; main unit approx. 10 kg, can be easily carried by hand |
|
Power requirements |
Battery powered (24 V, 19.2 Ah) or adapter powered (220 VAC, 50Hz) |
|
Working temperature |
(-15-45) °C |
|
Working humidity |
(0~95)%RH |
|
Detector |
Heating miniaturized dedicated flame ionization detector (FID) |
|
Limit of detection of FID |
0.1 ppm |
|
Repeatability |
Non-Methane Total Hydrocarbon Qualitative repeatability: ≤0.5%; Benzene series Qualitative repeatability: ≤1% Non-Methane Total Hydrocarbon Qualitative weight repeatability ≤2.0%; Benzene series Qualitative weight repeatability: ≤3% |
|
Measurement range |
0-30000 mg/m3 ; Non-Methane Total Hydrocarbon: 0.1~1000ppm(benzene) |
|
Analysis cycle |
≤2min (non-methane); ≤5min (Benzene series); |
|
Sampling probe temperature |
(0-180)°C |
|
Maximum humidity |
(0-200) °C |
|
Sample gas flow rate |
≥0.6L/min |
|
Carrier gas |
75 mL built-in high-pressure cylinder supply, high purity nitrogen, refillable |
|
Hydrogen |
75 mL built-in high-pressure cylinder supply, refillable, with optional hydrogen storage alloy |
|
Standard gas |
75 mL built-in high-pressure cylinder supply, from specialist gas supplier, refillable |
|
High pressure cylinder life |
operation time at 2000 psi ≥3 h |
|
Battery life |
Charging time <8h; operation time after full charge ≥4h (main unit + heating line) |